#virtualbox
Требуется на хост-машине Windows развернуть несколько виртуальных. Они сохранены
в одном файле VBox.ova (включая образы дисков и конфигурацию). В файле содержится 6
виртуальных машин. Ниже приведена конфигурация.
Disks: vmdisk1 5762867200 -1 http://www.vmware.com/interfaces/specifications/vmdk.html#streamOptimized
VBox-disk1.vmdk -1 -1
vmdisk2 14298431488 -1 http://www.vmware.com/interfaces/specifications/vmdk.html#streamOptimized
VBox-disk2.vmdk -1 -1
vmdisk3 16106127360 -1 http://www.vmware.com/interfaces/specifications/vmdk.html#streamOptimized
VBox-disk3.vmdk -1 -1
vmdisk4 5368709120 -1 http://www.vmware.com/interfaces/specifications/vmdk.html#streamOptimized
VBox-disk4.vmdk -1 -1
vmdisk5 10737418240 -1 http://www.vmware.com/interfaces/specifications/vmdk.html#streamOptimized
VBox-disk5.vmdk -1 -1
vmdisk6 26843545600 -1 http://www.vmware.com/interfaces/specifications/vmdk.html#streamOptimized
VBox-disk6.vmdk -1 -1
vmdisk7 10737418240 -1 http://www.vmware.com/interfaces/specifications/vmdk.html#streamOptimized
VBox-disk7.vmdk -1 -1
vmdisk8 16106127360 -1 http://www.vmware.com/interfaces/specifications/vmdk.html#streamOptimized
VBox-disk8.vmdk -1 -1
Virtual system 0:
0: Suggested OS type: "DOS"
(change with "--vsys 0 --ostype "; use "list ostypes" to list all possible
values)
1: Suggested VM name "DOS"
(change with "--vsys 0 --vmname ")
2: Number of CPUs: 1
(change with "--vsys 0 --cpus ")
3: Guest memory: 353 MB
(change with "--vsys 0 --memory ")
4: Sound card (appliance expects "", can change on import)
(disable with "--vsys 0 --unit 4 --ignore")
5: USB controller
(disable with "--vsys 0 --unit 5 --ignore")
6: Network adapter: orig NAT, config 2, extra slot=0;type=NAT
7: Floppy
(disable with "--vsys 0 --unit 7 --ignore")
8: CD-ROM
(disable with "--vsys 0 --unit 8 --ignore")
9: IDE controller, type PIIX4
(disable with "--vsys 0 --unit 9 --ignore")
10: IDE controller, type PIIX4
(disable with "--vsys 0 --unit 10 --ignore")
11: Hard disk image: source image=VBox-disk1.vmdk, target path=D:\VBox\DOS\VBox-disk1.vmdk,
controller=9;channel=0
(change target path with "--vsys 0 --unit 11 --disk path";
disable with "--vsys 0 --unit 11 --ignore")
Virtual system 1:
0: Suggested OS type: "Linux"
(change with "--vsys 1 --ostype "; use "list ostypes" to list all possible
values)
1: Suggested VM name "Gentoo"
(change with "--vsys 1 --vmname ")
2: Number of CPUs: 2
(change with "--vsys 1 --cpus ")
3: Guest memory: 3260 MB
(change with "--vsys 1 --memory ")
4: Sound card (appliance expects "", can change on import)
(disable with "--vsys 1 --unit 4 --ignore")
5: USB controller
(disable with "--vsys 1 --unit 5 --ignore")
6: Network adapter: orig NAT, config 3, extra slot=0;type=NAT
7: CD-ROM
(disable with "--vsys 1 --unit 7 --ignore")
8: IDE controller, type PIIX4
(disable with "--vsys 1 --unit 8 --ignore")
9: IDE controller, type PIIX4
(disable with "--vsys 1 --unit 9 --ignore")
10: SATA controller, type AHCI
(disable with "--vsys 1 --unit 10 --ignore")
11: Hard disk image: source image=VBox-disk2.vmdk, target path=D:\VBox\Gentoo\VBox-disk2.vmdk,
controller=10;channel=0
(change target path with "--vsys 1 --unit 11 --disk path";
disable with "--vsys 1 --unit 11 --ignore")
12: Hard disk image: source image=VBox-disk3.vmdk, target path=D:\VBox\Gentoo\VBox-disk3.vmdk,
controller=10;channel=1
(change target path with "--vsys 1 --unit 12 --disk path";
disable with "--vsys 1 --unit 12 --ignore")
Virtual system 2:
0: Suggested OS type: "WindowsXP"
(change with "--vsys 2 --ostype "; use "list ostypes" to list all possible
values)
1: Suggested VM name "MIS_ORACLE"
(change with "--vsys 2 --vmname ")
2: Number of CPUs: 1
(change with "--vsys 2 --cpus ")
3: Guest memory: 1024 MB
(change with "--vsys 2 --memory ")
4: Sound card (appliance expects "", can change on import)
(disable with "--vsys 2 --unit 4 --ignore")
5: USB controller
(disable with "--vsys 2 --unit 5 --ignore")
6: Network adapter: orig NAT, config 2, extra slot=0;type=NAT
7: Network adapter: orig Internal, config 2, extra slot=1;type=Internal
8: CD-ROM
(disable with "--vsys 2 --unit 8 --ignore")
9: IDE controller, type PIIX4
(disable with "--vsys 2 --unit 9 --ignore")
10: IDE controller, type PIIX4
(disable with "--vsys 2 --unit 10 --ignore")
11: Hard disk image: source image=VBox-disk4.vmdk, target path=D:\VBox\MIS_ORACLE\VBox-disk4.vmdk,
controller=9;channel=0
(change target path with "--vsys 2 --unit 11 --disk path";
disable with "--vsys 2 --unit 11 --ignore")
Virtual system 3:
0: Suggested OS type: "WindowsXP"
(change with "--vsys 3 --ostype "; use "list ostypes" to list all possible
values)
1: Suggested VM name "MUD_"
(change with "--vsys 3 --vmname ")
2: Number of CPUs: 1
(change with "--vsys 3 --cpus ")
3: Guest memory: 1881 MB
(change with "--vsys 3 --memory ")
4: Sound card (appliance expects "", can change on import)
(disable with "--vsys 3 --unit 4 --ignore")
5: USB controller
(disable with "--vsys 3 --unit 5 --ignore")
6: Network adapter: orig NAT, config 2, extra slot=0;type=NAT
7: CD-ROM
(disable with "--vsys 3 --unit 7 --ignore")
8: IDE controller, type PIIX4
(disable with "--vsys 3 --unit 8 --ignore")
9: IDE controller, type PIIX4
(disable with "--vsys 3 --unit 9 --ignore")
10: Hard disk image: source image=VBox-disk5.vmdk, target path=D:\VBox\MUD_\VBox-disk5.vmdk,
controller=8;channel=0
(change target path with "--vsys 3 --unit 10 --disk path";
disable with "--vsys 3 --unit 10 --ignore")
Virtual system 4:
0: Suggested OS type: "Windows7"
(change with "--vsys 4 --ostype "; use "list ostypes" to list all possible
values)
1: Suggested VM name "Win7"
(change with "--vsys 4 --vmname ")
2: Number of CPUs: 4
(change with "--vsys 4 --cpus ")
3: Guest memory: 5216 MB
(change with "--vsys 4 --memory ")
4: Sound card (appliance expects "", can change on import)
(disable with "--vsys 4 --unit 4 --ignore")
5: USB controller
(disable with "--vsys 4 --unit 5 --ignore")
6: Network adapter: orig NAT, config 3, extra slot=0;type=NAT
7: CD-ROM
(disable with "--vsys 4 --unit 7 --ignore")
8: IDE controller, type PIIX4
(disable with "--vsys 4 --unit 8 --ignore")
9: IDE controller, type PIIX4
(disable with "--vsys 4 --unit 9 --ignore")
10: SATA controller, type AHCI
(disable with "--vsys 4 --unit 10 --ignore")
11: Hard disk image: source image=VBox-disk6.vmdk, target path=D:\VBox\Win7\VBox-disk6.vmdk,
controller=10;channel=0
(change target path with "--vsys 4 --unit 11 --disk path";
disable with "--vsys 4 --unit 11 --ignore")
12: Hard disk image: source image=VBox-disk7.vmdk, target path=D:\VBox\Win7\VBox-disk7.vmdk,
controller=10;channel=1
(change target path with "--vsys 4 --unit 12 --disk path";
disable with "--vsys 4 --unit 12 --ignore")
Virtual system 5:
0: Suggested OS type: "WindowsXP"
(change with "--vsys 5 --ostype "; use "list ostypes" to list all possible
values)
1: Suggested VM name "WinXP_SQL"
(change with "--vsys 5 --vmname ")
2: Number of CPUs: 1
(change with "--vsys 5 --cpus ")
3: Guest memory: 2048 MB
(change with "--vsys 5 --memory ")
4: Sound card (appliance expects "", can change on import)
(disable with "--vsys 5 --unit 4 --ignore")
5: USB controller
(disable with "--vsys 5 --unit 5 --ignore")
6: Network adapter: orig Bridged, config 2, extra slot=1;type=Bridged
7: CD-ROM
(disable with "--vsys 5 --unit 7 --ignore")
8: IDE controller, type PIIX4
(disable with "--vsys 5 --unit 8 --ignore")
9: IDE controller, type PIIX4
(disable with "--vsys 5 --unit 9 --ignore")
10: Hard disk image: source image=VBox-disk8.vmdk, target path=D:\VBox\WinXP_SQL\VBox-disk8.vmdk,
controller=8;channel=0
(change target path with "--vsys 5 --unit 10 --disk path";
disable with "--vsys 5 --unit 10 --ignore")
При распаковке виртуальной машины Windows7 возникает ошибка
Progress state: E_FAIL VBoxManage.exe: error: Appliance import failed
VBoxManage.exe: error: Internal inconsistency looking up disk image
'vmdisk6' VBoxManage.exe: error: Details: code E_FAIL (0x80004005),
component Appliance, i nterface IAppliance VBoxManage.exe: error:
Context: "int __cdecl handleImportAppliance(struct Handle rArg *)" at
line 781 of file VBoxManageAppliance.cpp
Эта виртуальная машина не самая необходимая, но из-за неё невозможно распаковать
остальные. Пытался решить проблему так:
D:>vboxmanage import vbox.ova --vsys 3 --vmname MUD --vsys 4 --unit 4
--ignore --unit 5 --ignore --unit 7 --ignore --unit 8 --ignore --unit 9 --ignore
--unit 10 --ignore --unit 11 --ignore --unit 12 --ignore
То есть пытался отключить импорт этой машины. Не помогло, та же ошибка. Есть ли способ
вообще отключить импорт этой машины и диска vmdisk6?
Ответы
Ответ 1
Файл с расширением ova (File Virtualization Format Archive) это архив в формате tar. Попробуйте переименуйте свой файл VBox.ova в VBox.tar и распакуйте любым архиватором который поддерживает этот формат, тот же 7zip. Дальше можно импортировать неповрежденные машины.
Комментариев нет:
Отправить комментарий